Model |
Type |
Description |
Datasheet |
Manual |
|
NDIR sensor series |
IRNET-P |
NDIR |
'Intelligent'
microprocessor based NDIR sensor for
Hydrocarbons or Carbon Dioxide. D 20 mm
or 32 mm, 3 pin output standard (on
request 5 pin for RX/TX). |
|
|
IRNET-7 |
NDIR |
'Dummy' version NDIR
sensor for Hydrocarbons or Carbon
Dioxide. D 20 mm or 32 mm, 7 pin raw
signal output. |
|
|
IRPELL-P |
NDIR |
'Intelligent'
microprocessor based NDIR sensor for
Hydrocarbons or Carbon Dioxide. D 20 mm
or 32 mm, 3 pin full pellistor output
(on request 5 pin for RX/TX). |
|
|
IRNEX-P |
NDIR |
'Intelligent'
microprocessor based NDIR sensor for
Hydrocarbons or Carbon Dioxide. D 20 mm,
3 pin output standard (on request 5 pin
for RX/TX). ATEX explosion proof
component approved, IEC Ex certification
pending. |
|
|
IRPEX-P |
NDIR |
'Intelligent'
microprocessor based NDIR sensor for
Hydrocarbons or Carbon Dioxide. D 20 mm,
3 pin full pellistor output (on request
5 pin for RX/TX). ATEX explosion proof
component approved, IEC Ex certification
pending. |
|
|
IRIS-P |
NDIR |
'Intelligent'
microprocessor based NDIR sensor for
Hydrocarbons or Carbon Dioxide. D 32 mm,
3 pin output standard (on request 5 pin
for RX/TX). Intrinsically safe ATEX
certified. |
|
|
IRIS-7 |
NDIR |
'Dummy' version NDIR
sensor for Hydrocarbons or Carbon
Dioxide. D 20 mm or 32 mm, 7 pin raw
signal output. Intrinsically safe ATEX
certified. |
|
|
NDIR sensor series |
NDIR |
How to compose the part
number for all IR sensors |
|
|
NETC heads – full
conformity ATEX approved |
IRAD |
Sensor head |
Full conformity ATEX
explosion proof certified head in
stainless steel or aluminium, housing
NDIR sensor. |
|
|
NETC2 |
Sensor head |
Full conformity ATEX
explosion proof certified head in
stainless steel or aluminium, housing
pellistor, NDIR or electrochemical cell
sensor. |
|
|
NETC3 |
Sensor head |
Full conformity ATEX
explosion proof certified head in
stainless steel or aluminium, housing
pellistor, NDIR or electrochemical cell
sensor and possibly also PCB boards for
signal transmission. The head is made in
two parts and the sensor can be
replaced. |
|
|
NET heads – component
ATEX approved |
NET2 |
Sensor head |
ATEX explosion proof
certified head component in stainless
steel or aluminium, housing pellistor,
NDIR or electrochemical cell sensor. |
|
|
NET3 |
Sensor head |
ATEX explosion proof
certified head component in stainless
steel or aluminium, housing pellistor,
NDIR or electrochemical cell sensor and
possibly also PCB boards for signal
transmission. The head is made in two
parts and the sensor can be replaced. |
|
|
Genius |
Genius |
NDIR |
Genius sensor family -
dual technology sensors |
|
|
Catalytic sensors by
Nemototech |
NP-30 |
Catalytic |
General purpose matched
pair pellistor for fixed Systems with
poison resistance and excellent
stability. 2.0 V, 300 mA. |
|
|
NP-30S |
Catalytic |
Lower cost version of
NP-30H, mounted on single header. 2.0 V,
300 mA. |
|
|
NP-17 |
Catalytic |
Lower power matched pair
pellistor for fixed systems, with poison
resistance and excellent stability. 2.0
V, 175 mA. |
|
|
NP-17SH |
Catalytic |
Low cost version of
NP-17, mounted on single header. 2.0 V,
175 mA. |
|
|
NP-18 |
Catalytic |
General purpose matched
pair pellistor for fixed systems with
poison resistance and excellent
stability. 2.5 V, 170 mA. |
|
|
NP-18S |
Catalytic |
Lower cost version of
NP-18, mounted on single header. 2.5V,
170 mA. |
|
|
NP-AHS |
Catalytic |
Special Purpose pellistor
sensor designed to monitor low LEL
levels of Hydrogen. Poison resistant.
Single header. High temperature version.
1.6 V, 140 mA. |
|
|
NP-ANS |
Catalytic |
Special Purpose pellistor
sensor designed to monitor low LEL
levels of Ammonia. Poison resistant.
Single header. High temperature version.
2.2 V, 175 mA. |
|
|
NP-AC |
Catalytic |
Special Purpose pellistor
sensor designed to monitor LEL levels of
Acetylene. Poison resistant. Supplied as
matched pairs, mounted on twin TO4 size
headers. 2.0 V, 150 mA. |
|
|
Catalytic sensors by
N.E.T. |
NP-17SHM |
Catalytic |
Lower cost version of
NP-17, mounted on single header,
Standard size D 20.4mm X H 10.0mm. 2.0
V, 175 mA. |
|
|
NP-17SS(380) |
Catalytic |
The NP-17SS and NP-380
are (pellistor) type flammable gas
sensor supplied as a matched pair of
pellistor elements mounted on a phenolic
base single header. |
|
|
NP-30(21T) |
Catalytic |
The NP-30(21T) is a
catalytic (pellistor) type flammable gas
sensor supplied as a matched pair of
elements mounted on TO4 size headers and
protected by a metal can. |
|
|
NP-17SM |
Catalytic |
The NP-17SM is a
catalytic (pellistor) type flammable gas
sensor supplied as a matched pair of
pellistor elements mounted on a single
header, protected by a miniature
stainless steel enclosure and a phenolic
resin base. |
|
|
ATEX certified mini heads
by N.E.T. |
NET-4-10S |
Catalytic |
ATEX Certified miniature
plug-in sensor block including NP-10S
gas sensor. 4.25 V, 55 mA. |
|
|
NET-4-13S |
Catalytic |
ATEX Certified miniature
plug-in sensor block including NP-13S
gas sensor. 3.0 V, 75 mA. |
|
|
NET-5-10S |
Catalytic |
ATEX Certified miniature
plug-in block including NP-10S gas
sensor - Industry standard (16.5mm X
20mm) size. 4.25 V, 55 mA. |
|
|
NET-5-13S |
Catalytic |
ATEX Certified miniature
plug-in block including NP-13S gas
sensor - Industry standard (16.5mm X
20mm) size. 3.0 V, 75 mA. |
|
|
Electrochemical cells by
Nemototech |
NT-CO |
E.C. |
Standard Format
Electrochemical Carbon Monoxide sensor.
Range 0-1000 ppm. Output 75 nA/ppm. |
|
|
NT-H2S-1 |
E.C. |
Standard Format
Electrochemical Hydrogen Sulfide sensor.
Range 0-100 ppm. Output 700 nA/ppm. |
|
|
NT-NO2 |
E.C. |
Standard Format
Electrochemical Nitrogen Dioxide sensor.
Range 0-20 ppm. Output 600 nA/ppm. |
|
|
NT-CL2 |
E.C. |
Standard Format
Electrochemical Chlorine sensor. Range
0-10 ppm. Output 600 nA/ppm. |
|
|
NT-NO |
E.C. |
Standard Format
Electrochemical Nitrogen Oxide Sensor.
Range 0-250 ppm. Output 400 nA/ppm. |
|
|
Electrochemical cells by
N.E.T. |
NT-CO-S4 |
E.C. |
Electrochemical Carbon
Monoxide sensor, D 20 mm. Range 0-500
ppm. Output 70 nA/ppm. |
|
|
NT-O2-A2 |
E.C. |
Electrochemical Oxygen
sensor, D 20 mm. Range 0-25% vol. Output
80 to 120 µA @ 20.9% O2. |
|
|
Electrochemical cells by
N.E.T. premium line |
NT-CO-PL1000 |
E.C. |
Premium Line
Electrochemical Carbon Monoxide sensor.
Standard format. Range 0-1000 ppm.
Output 70 nA/ppm. |
|
|
NT-NH3-PL100 |
E.C. |
Premium Line
Electrochemical Ammonia sensor. Standard
format. Range 0-100 ppm. Output 40
nA/ppm. |
|
|
NT-NO2-PL30 |
E.C. |
Premium Line
Electrochemical Nitrogen Dioxide sensor.
Standard Format. Range 0-20 ppm. Output
600 nA/ppm. |
|
|
NT-H2S-PL100 |
E.C. |
Premium Line
Electrochemical Hydrogen Sulfide sensor.
Standard format. Range 0-100 ppm. Output
700 nA/ppm. |
|
|
NT-NH3-PL1000 |
E.C. |
Premium Line
Electrochemical Ammonia sensor. Standard
format. Range 0-1000 ppm. Output 8
nA/ppm. |
|
|
Solid electrochemical
cells by N.E.T. |
NT-CO-SS |
Solid E.C. |
Solid electrochemical
carbon monoxide sensor, D 20 mm. Range
0-1000 ppm. |
|
|
NT-H2S-SS |
Solid E.C. |
Solid electrochemical
hydrogen sulfide sensor, D 20 mm. Range
0-100 ppm. |
|
|
NT-O2-SS |
Solid E.C. |
Solid electrochemical
oxygen sensor, D 20 mm. Range 0-25% vol. |
|
|
NT-H2-SS |
Solid E.C. |
Solid electrochemical
hydrogen sensor, D 20 mm. Range 0-100
%LEL. |
|
|
Smart gas sensor modules
for OEM manufacturers |
REMORA-CO |
Transmitter module |
Double board module
featuring voltage and I2C outputs |
|
|
REMORA L |
Transmitter module |
Single board module
featuring digital and analogue output
for residential and fire detectors |
|
|
CYBER TTL |
Transmitter module |
Single board module
featuring voltage and digital (TTL)
outputs |
|
|
CYBER TX |
Transmitter module |
Multi board module
featuring 4-20 mA and digital (RS485
MODBUS) outputs |
|
|
Gas sensors for non
hazardous areas (hydrogen, car parks,
buildings and residential applications) |
NET-656 |
Catalytic |
Low cost catalytic
flammable gas sensor, optimised for
Detecting LNG and LPG. Metal enclosure,
for residential gas detectors. |
|
|
NT-CO-LI |
E.C. |
As NT-CO but slightly
lower specification with lower cost.
Developed especially for light
industrial applications and car parks
detection. Range 0-1000 ppm. Output 50
nA/ppm. |
|
|
NT-H2S-LI |
E.C. |
As NT-H2S-1 but with
slightly lower specification and lower
cost. Developped especially for light
industrial applications. Range 0-100
ppm. Output 500 nA/ppm. |
|
|
NT-NO2-PK |
E.C. |
As NT-NO2 but slightly
lower specification with lower cost.
Developed especially for car parks
detection. Range 0-30 ppm. Output 600
nA/ppm. |
|
|
NT-CO-SLI |
E.C. |
As NT-CO but slightly
lower specification with lower cost.
Developed especially for light
industrial applications and car parks
detection. Range 0-1000 ppm. Output 50
nA/ppm. |
|
|
NT-CO-S9 |
E.C. |
New low profile (D 14.5
mm x H8.3 mm) CO sensor developped
especially for light industrial
applications and car parks detection. |
|
|
NT-CO-SR |
Solid E.C. |
Solid Electrochemical
Carbon Monoxide sensor for residential
and car parks applications. Round slim
format. Range 0-1000 ppm. Output 10-50
nA/ppm. |
|
|
NT-CO-SF |
Solid E.C. |
Solid Electrochemical
Carbon Monoxide sensor for residential
and car parks applications. Flat format.
Range 0-1000 ppm. Output 10-50 nA/ppm. |
|
|
NT-H2-SR |
Solid E.C. |
Solid Electrochemical
Hydrogen sensor for residential and car
parks applications. Round format. Range
0-50 %LEL. Output 0.4-10 nA/ppm. |
|
|
NT-H2-SF |
Solid E.C. |
Solid Electrochemical
Hydrogen sensor for residential and car
parks applications. Flat format. Range
0-50 %LEL. Output 0.4-10 nA/ppm. |
|
|
RE-SAF-CO |
Solid E.C. |
REMORA CO, solid
electrochemical CO sensor with
integrated SAFE® circuit. |
|
|
NT-NO2-SF |
Solid E.C. |
Solid Electrochemical
Nitric Dioxide sensor for residential
and car parks applications. Flat format.
Range 0-100 ppm. Output 0-30 nA/ppm. |
|
|
NT-NO2-SR |
Solid E.C. |
Solid Electrochemical
Nitric Dioxide sensor for residential
and car parks applications. Round slim
format. Range 0-100 ppm. Output 10-30
nA/ppm. |
|
|
RE-SAF-NO2 |
Solid E.C. |
REMORA NO2, solid
electrochemical NO2 sensor with
integrated SAFE® circuit. |
|
|
Accessories |
NET-CKD |
Accessories |
Portable Digital
Controller for Calibration of All Cyber
devices |
|
|
IR-P-KIT-DEMO |
Accessories |
IR sensor evaluation
board |
|
|
CYBER-KIT-DEMO |
Accessories |
CYBER modules evaluation
board |
|
|
NET-GD2 - Dust Protection
Adapter Type 2 |
Accessories |
Combustible dust
protection adapter for type 2 head |
|
|
NET-GD3 - Dust Protection
Adapter Type 3 |
Accessories |
Combustible dust
protection adapter for type 3 head |
|
|
NET-CONE2 / NET-CONE3 -
Collector Cone |
Accessories |
Spun Aluminium Collector
cone to enhance performance with gas
significantly lighter than air.
Available for NET type 2 and type 3
head. |
|
|
NET-CAP2 / NET-CAP3 -
Calibration / Sampling Cap |
Accessories |
Stainless Steel screw-fit
assembly for calibration or as a
permanent sampling hood. Available for
NET head type 2 and 3. |
|