Electrochemical Oxygen Gas
Sensor (SS1118) |
|
Elctrochemical oxygen gas
sensor(SS1118) is of a
galvanic cell type. SS1118
measure partial pressure of
oxygen in air. SS1118
controls oxygen flow with
non-porous membrane. SS1118
requires no special
preparation or
calibration-just plugs it
into your interface then it
is ready to take readings.
SS1118 offers superior
performance over the
conventional oxygen sensor
in the fact that SS118 is
not affected by CO2, CO and
NOx. SS1118 also show fast
response property, high
stability and a long life
time. |
|
|
|
Electrochemical Oxygen Gas
Sensor (SS2118) |
|
Electrochemical Oxygen Gas
sensor Electrochemical
oxygen gas sensor(SS2118)
controls oxygen gas flow
with micro capillary hole.
The output of SS2118 is
linearly proportional to the
oxygen concentration in the
range of 0~30%. SS2118
doesn't measure the partial
pressure of oxygen but the
volume percent of oxygen in
air. The output of SS2118 is
very stable under
operational temperature
range. |
Operating Condition |
Sensor |
Qxygen(SS1118) |
Qxygen(SS2118) |
Temperature range |
-20~50℃ |
-10~50℃ |
Relative humidity range |
0~99%
RH |
0~99%
RH |
Pressure range |
Atmospheric±10% |
Atmospheric±10% |
Specifications |
Detection gas |
Qxygen(O2) |
Qxygen(O2) |
Detection range |
0~99% |
0~30% |
Output
signal |
6±1mV
in air |
90±20μA
in air |
Response time (T90) |
≤ 10
sec |
≤ 15
sec |
Typical
baseline range |
≤ 0.1% |
≤ 0.1% |
Output
linearity |
linearity |
linearity |
Repeatability |
± 0.5% |
± 0.5% |
Expected lifetime |
2year |
2year |
Physical Characteristics
Applications |
Weigh |
6 |
16g |
Dimension |
φ~20.4mm, h~16.6mm |
φ~20.4mm, h~16.6mm |
Storage
life |
3
months |
6
months |
Warranty period |
18
months |
24
months |
Applications |
Combustion effciency
analyzer, Food storage, Gas
mixer, Medical sensor, Scuba
sensor, Dissolved oxygen
|
Ideal
for portable instrument,
Industry,safety, boiler room
etc. |
|
|
|
|
|
|
Hydrogen sulfide Sensor
(SS1198) |
|
The electrochemical hydrogen
sulfide gas sensor(SS1198)
measures the concentration
of H2S with a spontaneous
oxidation-reduction
reaction. SS1198 has a high
selectivity, good
reproducibility, small
output drift and no power
consumption. SS1198 is very
suitable for the gas
detectors required in the
fields such as
petrochemical, mine, waste
water plant, etc. |
Operating condition
|
Sensor |
Hydrogen sulfide(SS1198) |
Temperature range |
-20~50℃ |
Relative humidity range |
15~90% RH |
Pressure range |
Atmospheric±10% |
Performance |
Detection gas |
Hydrogen sulfide(H2S) |
Detection range |
0~500ppm |
Output
signal |
60±15nA/ppm |
Response time (T90) |
≤ 30 sec |
Typical
baseline range |
-1 to 1ppm |
Output
linearity |
linearity |
Repeatability |
± 2% |
Expected lifetime |
2year |
Physical Characteristics &
Applications |
Weigh |
6 |
Dimension |
φ~20.4mm, h~16.6mm |
Storage
life |
6
months |
Warranty period |
24 months |
Application field |
Portable & fixed gas
detector,
Industrial
safety(petrochemical,
refining)
Waste water, Sewage
treatment plant, Mine, etc
|
|
|
|
|
|
|
Electrochemical Carbon
Monoxide Gas Sensor
(SS1128) |
|
The electrochemical carbon
monoxide gas sensor(SS1128)
has a superior gas
selectivity to CO. The
output signal of SS1128 is
linearly proportion to the
CO gas concentration in air.
SS1128 is little affected by
humidity change. SS1128 also
offers superior performance
over the conventional
semiconductor type in that
SS1128 has a high
selectivity, good
reproducibility, small
output drift and no power
consumption |
Operating condition
|
Sensor |
Carbon
monoxide(SS1128) |
Temperature range |
-20~50℃ |
Relative humidity range |
15~90% RH |
Pressure range |
Atmospheric±10% |
Performance |
Detection gas |
Carbon monoxide(CO) |
Detection range |
0~1,000 ppm |
Output
signal |
60±15nA/ppm |
Response time (T90) |
≤ 30 sec |
Typical
baseline range |
-2 to 3ppm |
Output
linearity |
linearity |
Repeatability |
± 2% |
Expected lifetime |
2year |
Physical Characteristics &
Applications |
Weigh |
6 |
Dimension |
φ~20.4mm, h~16.6mm |
Storage
life |
6
months |
Warranty period |
18
months |
Applications |
Portable&Fixed gas detector,
Gas monitor, Petrochemical,
Mine Boiler room, etc. |
|
|
|
|
|
|
Hydrogen Sensor
(SS1178)
|
|
The electrochemical
hydrogen gas
sensor(SS1178)
measures the
concentration of H2
with a spontaneous
oxidation-reduction
reaction. SS1178 has
a high selectivity,
good
reproducibility,
small output drift
and no power
consumption. SS1178
is very suitable for
the gas detectors
required in the
fields such as
petrochemical, mine,
waste water plant,
etc. |
Operating condition
|
Sensor |
Hydrogen (SS1178) |
Temperature range |
-20~50°C |
Relative humidity
range |
15~90% RH |
Pressure range |
Atmospheric±10% |
Performance |
Detection gas |
Hydrogen (H2) |
Detection range |
0~1000ppm |
Output signal |
15±10nA/ppm |
Response time (T90) |
< 30 sec |
Typical baseline
range |
0 to 30ppm |
Output linearity |
linearity |
Repeatability |
± 2% |
Expected lifetime |
2year |
Physical
Characteristics &
Applications |
Weigh |
6 |
Dimension |
ø~20.4mm, h~16.6mm |
Storage life |
6 months |
Warranty period |
24 months |
Application field |
Portable & fixed gas
detector,
Industrial
safety(petrochemical,
refining)
Waste water, Sewage
treatment plant,
Mine, etc |
|
|
|
|
|
|
|
Certified version using
flameproof protection type
Exd. Typically used in
portable apparatus for
hazardous locations. ATEX,
IECEx, UL and cUL approved |
|
GAS TYPE |
SENSOR RANGE |
COMMENTS |
METHANE |
0 - 5% volume |
Fully characterised for
methane. |
METHANE |
0 - 100% volume |
Fully characterised for
methane |
METHANE |
0 - 100% volume |
High resolution version
measures methane from 0 to
100% volume with resolution
of 0.01 % for 0-10% methane
and 0.1% for 10-100% volume. |
PROPANE |
0 - 2% volume |
Fully characterised for
propane.
Cross-reference factors
available for: Butane,
Pentane, Hexane, Ethanol,
Ethylene, Propylene, Ethane,
Cyclopentane,
Isopropanol, Methanol,
Toluene, Acetone, Methyl
ethyl ketone (MEK) and
Xylene , see Note 1 |
PROPANE |
0 - 100% volume |
Fully characterised for
propane |
PROPYLENE |
0 - 2% volume |
Fully characterised for
propylene |
BUTANE |
0 - 2% volume |
Fully characterised for
butane |
PENTANE |
0 - 2% volume |
Fully characterised for
pentane |
HEXANE |
0 - 1% volume |
Sensor output linearised for
hexane, see Note 1 |
ETHYLENE |
0 - 3% volume |
Sensor output linearised for
ethylene, see Note 1 |
ETHANE |
0 - 3% volume |
Fully characterised for
ethane |
ETHYLENE OXIDE |
0 - 3% volume |
Fully characterised for
ethylene oxide |
ETHANOL |
0 - 5% volume |
Sensor output linearised for
ethanol, see Note 1 |
METHYL BROMIDE |
0 - 25,000 ppm |
Sensor output linearised for
methyl bromide, see Note 1 |
Note 1: Temperature
performance may vary from
the specifications on the
hydrocarbon sensor data
sheets. Refer to data sheet
TDS0050 on the Dynament
website for further
information. |
|
|
|
|
|
|
Certified version using
flameproof protection type
Exd. Typically used in
portable apparatus for
hazardous locations. ATEX,
IECEx, UL and cUL approved
|
|
PREMIER
CARBON DIOXIDE SENSORS
|
GAS TYPE |
SENSOR RANGE |
RESOLUTION |
CARBON DIOXIDE |
0 - 500 ppm |
10 ppm from 0 to 250 ppm,
then 20 ppm up to FSD |
CARBON DIOXIDE |
0 - 1000 ppm |
20 ppm from 0 to 500 ppm,
then 40 ppm up to FSD |
CARBON DIOXIDE |
0 - 2000 ppm |
50 ppm from 0 to 1000 ppm,
then 100 ppm up to FSD |
CARBON DIOXIDE |
0 - 5000 ppm |
50 ppm from 0 to 2500 ppm,
then 100 ppm up to FSD |
CARBON DIOXIDE |
0 - 10,000 ppm |
100 ppm from 0 to 5000 ppm,
then 200 ppm up to |
CARBON DIOXIDE |
0 - 2% volume |
0.025% vol from 0 to 1% vol,
then 0.05% vol up to FSD |
CARBON DIOXIDE |
0 - 5% volume |
0.025% vol from 0 to 2.5%
vol, then 0.05% vol up to
FSD |
CARBON DIOXIDE |
0 - 100% volume |
0.5% vol from 0 to 50% vol,
then 1% vol up to FSD |
|
|
|
|
|
Gas Type |
Detecting
Range |
Sampling
Method |
Permissible
Standards |
LEL(%Vol) |
Specific
Gravify |
O₂ |
0 - 30% |
Electrochemical
|
19.5% ~ 23.5% |
- |
1.11 |
CO |
0 -1,000ppm |
Electrochemical
|
25ppm |
12.5 |
0.968 |
H₂S |
0 - 500ppm |
Electrochemical
|
10ppm |
4.3 |
1.19 |
SO₂ |
0 - 20ppm |
Electrochemical
|
2ppm |
- |
2.26 |
H₂ |
0 - 1,000ppm |
Electrochemical
|
- |
4% vol |
0.07 |
NH₃ |
0 - 50ppm |
Electrochemical
|
25ppm |
15 |
0.6 |
CI₂ |
0 - 100ppm |
Electrochemical
|
1ppm |
- |
2.49 |
HCI |
0 -
30ppm |
Electrochemical
|
5ppm |
- |
1.27 |
HCN |
0 - 100ppm |
Electrochemical
|
10ppm |
5.6 |
0.941 |
O₃ |
0 - 2ppm |
Electrochemical
|
0.1ppm |
- |
1.65 |
NO |
0 - 1,000ppm |
Electrochemical
|
25ppm |
- |
1.53 |
NO₂ |
0 - 150ppm |
Electrochemical
|
3ppm |
- |
1.58 |
PH₃ |
0 - 20ppm |
Electrochemical
|
0.3ppm |
1 |
1.18 |
SiH₄ |
0 - 50ppm |
Electrochemical
|
5ppm |
13.5 |
1.11 |
CO₂ |
0 - 15,000ppm |
NDIR |
5000ppm |
- |
1.5 |
0 - 500ppm
up to 0 - 5% Vol |
IR |
Hydrocarbons |
0 - 100% Vol |
IR |
- |
- |
- |
C₄H10 |
0 - 2% Vol |
IR |
- |
1.86 |
2.00 |
C₂H6 |
0 - 3% Vol |
IR |
- |
3.00 |
1.00 |
CH₃CH₂OH |
0 - 5% Vol |
IR |
- |
3.60 |
1.60 |
C₂H₄ |
0 - 3% Vol |
IR |
- |
2.75 |
1.00 |
C₂H₄O |
0 - 3% Vol |
IR |
- |
3.00 |
1.50 |
CH₃(CH₂)₄CH₃ |
0 - 1% Vol |
IR |
- |
1.20 |
3.50 |
CH₄ |
0 - 5% or
0 - 100% Vol |
IR |
- |
5.00 |
0.55 |
C-H₃Br |
0 - 25,000ppm |
IR |
- |
10.00 |
3.30 |
N₂O |
0 - 1000ppm
up to 0-1% Vol |
IR |
50ppm |
- |
1.53 |
C5H12 |
0 - 2% Vol |
IR |
- |
1.5 |
2.5 |
CH₃CH₂CH₃ |
0 - 2% Vol |
IR |
- |
2.20 |
1.50 |
|
|
|
|
|
|
SPECIFICATION |
Sensor Type |
Electrochemical,
Catalytic, IR sensor
(Oxygen, Carbon monoxide, Hydrogen Sulfide,
Hydrogen, Ammonia, Sulfur Dioxide, Nitrogen Dioxide,
Nitric Oxide, Combustible (CH4) ) |
Dimensions |
Main board : 67 mm x
27 mm x 36 mm
Small sensor board : 21 mm x 27 mm |
Input Voltage |
Analog 10-30 V DC or
Digital 5 V DC |
Analog Signal Outputs
|
4-20mA |
Digital Signal Outputs
|
TTL ( 3V Level )
TTL Parameter
Baud rate : 9600 bps, Parity : none, Stop bit : 1,
Data bit : 8 |
Calibration Switch |
O2 : ZERO Calibration
10 sec, SPAN Calibration 3-8 sec
More Type : ZERO Calibration 3-8 sec, SPAN
Calibration 10 sec |
|
|
|
|
|
|
|
SPECIFICATION |
Target Gases |
Odorous gases such as ammonia and
H2S, volatile organic compounds (VOC), hydro carbons
(HC) and ethanol |
CO2 |
Detecting Method |
Metal oxide semiconductor |
Non Dispersive Infrared (NDIR) |
Input Voltage |
5 to 12VDC |
Signal Outputs |
RS 232 / RS 485 |
Applications |
Air cleaners, Ventilation
control, Air quality monitors, VOC monitors, Odor
monitors |
CO2 monitor |
|
日本Figaro气体传感器选型
日本NEMOTO气体传感器
日本FIS气体传感器
英国CITY城市气体 CITY公司/IT公司/SENSORIC公司气体传感器选购指南
英国Alphasense气体传感器选型
瑞士Membrapor气体传感器选型
德国IT公司气体传感器选购资料 德国SENSORIC公司气体传感器 RAE气体传感器气体检测仪 意大利森斯特传感器
Dittrich气体产品
国产气体传感器选型
DCS公司红外产品
VTI公司红外产品
SENSORS公司红外热导产品
爱丁堡公司红外产品Honeywell传感器
SHINYEI传感器
E2V传感器
GE传感器SMARTGAS传感器MSI传感器MEAS传感器
英国SSC气体检测 宝亚呼吸防护设备 Dynament气体传感器德国Schutz
NDIR 红外气体传感器美国MAXTEC产品 美国Teledyne气体分析仪及氧传感器
美国AMI氧分析仪及传感器 美国AII氧分析仪传感器 Sensors
Direct 加拿大BW科技日本新宇宙NEW
COSMOSSERVOMEX气体分析英国GSS气体传感器英国SST传感器 southland
sensing EnviteC安维特 韩国SYHITECH 韩国SENKO
韩国SOHA 韩国KNC(NEWCERA)
韩国KOREA
DIGITAL 韩国ELT
SUNSTAR气体传感器
电化学气体传感器
半导体气体传感器
催化燃烧式气体传感器
固体电解质气体传感器
热传导式气体传感器
红外气体传感器
离子烟雾传感器
机动车用气体传感器
气体变送器/检测仪
O2氧气传感器专场
CO2二氧化碳传感器专场
CH4甲烷传感器专场
室内空气质量监测控制
温湿度监测控制
医疗设备用传感器
红外气体分析元件1
红外气体分析元件2
红外气体分析元件3
激光红外气体分析元件1
激光红外气体分析元件2
激光红外气体分析元件3
气体变送器模块
BW便携式气体检测仪
BW固定式气体检测仪CO传感器
S02传感器H2S传感器
NH3传感器
NO传感器
NO2传感器
CH2O传感器
CL2传感器
HCL传感器
H2传感器O3传感器C2CL4传感器C2H4传感器
HF传感器
HBR传感器
COCL2传感器
HCN传感器
ASCL3传感器
ASF3传感器C4H6传感器
CLO2传感器
SIH2CL2传感器
(CH3传感器NH传感器
GeCL4传感器
I2传感器
PCL3传感器
SICL4传感器
SO2F2传感器
酒精传感器其它 |