TEC O2 Sensors
		The TEC line of oxygen sensors by Maxtec fulfills virtually any 
		customer application. This sensor line provides Maxtec with several 
		additional options when it comes to oxygen sensor replacement in various 
		applications and are all backed by Maxtec warranty and service. Contact 
		Maxtec today for your OEM needs!  
		
		
		Maxtec 氧气传感器中文资料及替换表下载
		
		TEC-101
		Part Number: T100P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
				- Analytical Industries [PSR-11-33-1] 
				
- Hamilton [HM-01, Veolar, Amadeus, Arabella] 
				
- Hudson RCI [See Teleflex Medical] 
				
- Maxtec [Max-19] 
				
- Mercury Medical [10-103-00] 
				
- Pacifitech [PT-01] 
				
- Teledyne [T1 #A-37016] 
				
- Teleflex Medical [5568 C1, C-01]
 
			Range: 0-100%
			Output @ Room Air: 200µA ± 20% 
			Response Time: 15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-103A
		Part Number: T103P10
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 14 mV ± 20%
			Response Time: 7 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-105
		Part Number: T105P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
				- Hudson 5500 
				
- Maxtec [Max-9]
 
			Range: 0-100% O2
			Response Time: 11 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-108
		Part Number: T108P01
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
				- Maxtec [Max-17] 
				
- Pacifitech [PT-08A]
 
			Range: 0-100% O2
			Output @ Room Air: 14 mV ± 20%
			Response Time: 7 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-108A
		Part Number: T108P10
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
				- Maxtec [Max-17] 
				
- Mindray Datascope [AS 3000] 
				
- Suitable for use with Nitrous Oxide (N2O)
 
			Range: 0-100% O2
			Output @ Room Air: 8 mV - 15 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-111A
		Part Number: T111P05
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 7.7 mV - 13 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-111AV
		Part Number: T111P10
		
			
				 
 
				6 month warranty
				Œ
 
			Replacement For:
			
				- Invivo Research Inc. #9445 
				
- Suitable for use with Nitrous Oxide (N2O)
 
			Range: 0-100% O2
			Output @ Room Air: 10 mV - 18 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-111
		Part Number: T111P01
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 7.5 mV - 13 mV 
			Response Time: 7 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-112
		Part Number: T112P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100%
			Output @ Room Air: 10 mV - 17 mV 
			Response Time: 7 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-112A
		Part Number: T112P05
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 10 - 17 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-114A
		Part Number: T114P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100%
			Output @ Room Air: 30µA ± 30% per Cathode 
			Response Time: 15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-116
		Part Number: T116P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 9 - 15 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-120A
		Part Number: T120P01
		
			
				 
 
				 
				Œ
 
			Replacement For:
			
			 
			Range: %
			Output @ Room Air: 
			Response Time: 
			 
			
		
		
		Back to 
		Top
		
		
		TEC-122i
		Part Number: T122P05
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 7.5 mV - 13 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-122
		Part Number: T122P01
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100%
			Output @ Room Air: 7.5 mV - 12 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-123A
		Part Number: T123P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
				- Call for applications 
				
- Suitable for use with Nitrous Oxide (N2O)
 
			Range: 0-100% O2
			Output @ Room Air: 7.5 mV - 13 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-125A
		Part Number: T125P10
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 9 mV - 15 mV 
			Response Time: 10 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-126
		Part Number: T126P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 10 mV - 17 mV 
			Response Time: 7 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-165
		Part Number: T165P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 200µA ± 20%
			Response Time: 15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-250
		Part Number: T125P01
		
			
				 
 
				14 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 8 mV - 15 mV 
			Response Time: 15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-505-1
		Part Number: T155P01
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 9.5 mV - 13.5 mV 
			Response Time: <15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-505-1AS
		Part Number: T155P10
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 11.0 mV - 15.5 mV 
			Response Time: <15 seconds
			 
			
		
		
		Back to 
		Top
		
		
		TEC-505-5
		Part Number: T155P05
		
			
				 
 
				12 month warranty
				Œ
 
			Replacement For:
			
			 
			Range: 0-100% O2
			Output @ Room Air: 9.5 mV - 13.5 mV 
			Response Time: <15 seconds